DCS # | DEMONSTRATION | REFERENCE | ABSTRACT |
5G40.00 | Hysteresis | | |
5G40.10 | hysteresis loop on scope | PIRA 500 | |
5G40.10 | hysteresis loop on scope | 5G40.10 | Show the hysteresis loops for laminated steel and ferrite cores as saturation is reached. |
5G40.10 | hysteresis loop | Es-10 | The hysteresis loop of a core is displayed on an oscilloscope. |
5G40.10 | hysteresis curve | Disc 20-28 | The Leybold setup shown on a scope. |
5G40.11 | hysteresis loop on scope | E-101 | The hysteresis loop for the iron core of a transformer is shown on a oscilloscope. Diagram and circuit hints. |
5G40.12 | hysteresis on the scope | 32-3.17 | A
circuit for showing the hysteresis curve of a transformer on an oscilloscope.
Also modifications for using various cores and coils. |
5G40.13 | improved hysteresis loop on scope | AJP 55(10),933 | A circuit, Hall probe, and storage oscilloscope allow plotting the hysteresis loop point by point or automatically. |
5G40.14 | hysteresis without induction | AJP 34(10),960 | Two
coils are mounted on a rotating disk in the air gap of an electromagnet.
As the field is varied, the hysteresis loop is plotted. |
5G40.15 | hysteresis loop | AJP 58(8),794 | This circuit makes it possible to display hysteresis loops of inductors with only one winding. |
5G40.16 | hysteresis on x-y | AJP 39(8),964 | An op amp circuit for plotting the hysteresis curve slowly on an x-y recorder. |
5G40.20 | magnetization and hysteresis | E-100 | A
small mirror on a compass needle is used to detect the magnetic field as
the current to a solenoid containing an iron bar is increased and decreased
stepwise. |
5G40.21 | simple hysteresis | E-10C | Parallel iron bars suspended in a coil show hysteresis when slowly magnetized and demagnetized. |
5G40.25 | hysteresis plot | 32-3.13 | A ballistic
galvanometer search coil gives readings of the magnetization and residual
magnetization of a sample as it is magnetized in opposite directions and
a plot is generated. |
5G40.27 | plotting hysteresis | 32-3.25 | A core with a removable link and built in flux meter are used to plot a hysteresis curve. |
5G40.31 | hysteresis in a motor | 32-3.15 | The I V curve from a generator is proportional to the normally obtained B H curve. |
5G40.41 | hysteresis loop with old tv | 32-3.14 | The hysteresis loop of a sample placed in one deflection coil is traced on an old TV tube. |
5G40.50 | hysteresis waste heat | PIRA 1000 | |
5G40.50 | hysteresis waste heat | Disc 20-29 | Water is boiled by magnetic hysteresis waste heat. |